Demo application
8.2 Creating a custom application
Figure 8-2
Create your own "Autonomous reading" application
Requirements: A corresponding configuration is stored in the reader.
Follow the steps below to create your own application for autonomous reading of the
transponder data:
1. Establish the connection to the reader ("brp_open_usb_session" or
"brp_open_serial_session").
2. Switch on Autoread mode ("Autoread_SetMode" / "exec_command", devcode = 0x05,
cmdcode = 0x00, param = 0x01 or 0x02)
– The transponder is recognized automatically.
– Read out the transponder data ("Autoread_GetMessage" / "exec_command", devcode =
The source code of the demo application can serve as an example for your own application.
74
"Read serial number" flow diagram
0x05, cmdcode = 0x01)
Operating Instructions, 05/2023, C79000-G8976-C432-10