Installation
3. Optional: Depending on your requirements, install the card holder or the cleanroom cover.
– When using a card holder:
– When using the reader in a cleanroom:
4. Push the reader through the mounting opening intended for this purpose (76.5 [± 0.3] ×
48.5 [± 0.3] mm)
Make sure that the reader locks in place so that it cannot fall out.
5. Mount the cover plate on the rear of the reader with the 4 Torx screws (max. 1.5 Nm)
6. Attach the reader by tightening the 4x stud screws
Ensure that the reader housing is flush with the base and that the circumferential gap is < 0.5
mm.
Figure 4-2
7. Optionally when using the reader in a cleanroom:
Apply a silicone joint on the front between the reader edge or the cleanroom cover and the
surface or the wall.
20
Place the card holder on the side of the reader housing and press it over the reader front
so that the card holder locks in place.
Note that you cannot use the card holder in combination with the cleanroom cover.
Place the cleanroom cover on the side of the reader housing and press it over the reader
front so that the cover locks in place.
Note that you cannot use the cleanroom cover in combination with the card holder.
.
In-wall installation of the SIMATIC RF1000 reader
.