Vhl_Read - Siemens SIMATIC RF1000 Operating Instructions Manual

Hide thumbs Also See for SIMATIC RF1000:
Table of Contents

Advertisement

Programming
7.3 Programming via the RS232 interface (using the Freeport protocol)
Table 7-40
Byte
0
1
2
3
4
5
6
7.3.2.9

vhl_read

Max. reader response time: 3 s
Table 7-41
Byte
0
1
2
3
4
5
6
7
8
9
10
Table 7-42
Byte
0
1
2
3
4
5 ... 12
13
62
Response telegram with errors
Value
Description
0x8C
Without checksum
0x9C
With checksum
0x01
DevCode of the command set containing the command to be called.
0x04
CmdCode of the command to be called.
0x01
Parameter length (e.g. 1 byte)
0x00
0x02
CARD_NOT_SELECTED_ERR
0x9A
Optional checksum (when the value "0x9C" is set in byte 0)
Request telegram
Value
Description
0x0C
Without checksum
0x1C
With checksum
0x01
DevCode of the command set containing the command to be called.
0x02
CmdCode of the command to be called.
0x05
Parameter length (e.g. 5 bytes)
0x00
0xFF
ID of the VHL function (e.g. 0xFF [factory setting for ISO 15693])
0x00
Address (e.g. 0x37)
0x37
0x00
Length (e.g. 0x08)
0x08
0xXX
Optional checksum (when the value "0x1C" is set in byte 0)
Response telegram without errors
Value
Description
0x0C
Without checksum
0x1C
With checksum
0x01
DevCode of the command set containing the command to be called.
0x02
CmdCode of the command to be called.
0x08
Parameter length (e.g. 8 bytes)
0x00
0xCC
Read data (e.g. 0xCC)
0xXX
Optional checksum (when the value "0x1C" is set in byte 0)
Operating Instructions, 05/2023, C79000-G8976-C432-10