The following message is displayed depending on the module type setting, the mounted module type, and the
module mount condition.
Module Type
parameter
NONE
No module installed.
U4
No module installed.
BA704-RFID-U4-S
BA704-RFID-U4-KR-S
BA704-RFID-U4-EU-S
BA704-RFID-U4-AU-S
preinstall model
*1: Selectable country codes differ depending on the RFID module type. Multiple country codes may be
displayed when setting a country code, but be sure to select the country where the RFID module is used.
Setting a different country code is prohibited.
Refer to "Module revision and LCD display" in "8.4.2. AUTO DIAGNOSTIC" for the countries where each
RFID module is used.
8.10.2.3 TAG
Set the tag type of the RFID module.
* Selectable tag types vary according to the module setting.
When using RFID with BA400, set module type with U4 and tag type with EPC C1 Gen2.
Module type
NONE
UHF band (U4)
Module type and status
Country of use
set (*1)
No country
setting
Tag type
NONE
I-Code
Tag-it
C220
ISO15693
C210
C240
C320
EPC C1 Gen2
NONE
EPC C1 Gen2
NONE
No RFID Module
[PAUSE] for Setting
Need Setting for use
[PAUSE] for Setting