8.5.5.1. PRE PEEL OFF POS
Fine adjustment position setting when "Yes / ON (with pre-peeling operation)" is specified in "Pre-peeling
treatment / PRE PEEL OFF".
Max.
Min. value
value
+9.9
-2.5
1. Select parameter settings
2. Select pre-stripping
settings
3. Select pre-peeling fine
adjustment
4. Test mode operation
selection
5. After test mode operation
(Supplement)
The print stop position at the time of peeling issuance is stopped so that the distance from the center of the
gap between labels to the tip of the peeling table is 4.0 mm. Assuming a gap between labels of 2.0mm, the
pre-peeling distance is 6.0mm by default. This is because 1.0 to 2.0 mm of the distance sent forward from
the peeling table by the pre-peeling operation is significant.
Step
Display
0.1
Decimal
Display
<2>SET PARAMETERS
FW/BK ACT.
MODE1
PRE PEEL OFF
BACK FEED SPEED STD
AUTO HEAD CHK
▼
Press the [PAUSE] key. ↓
PRE PEEL OFF
OFF
ON
▼
Press the [PAUSE] key. ↓
PRE PEEL OFF POS.
+1.0mm
( -2.5 -
+9.9 ) mm
Press the [PAUSE] key. ↓
PRE PEEL OFF POS.
TEST or SET
[F] TEST
[P]SET
Press the [FEED] key. ↓
PRE PEEL OFF POS.
ADJUST or SET
[R]ADJUST
[P]SET
Press the [PAUSE] key. ↓
Move back to the "Set
Parameters" screen after
back feeding the distance fed
in the test mode.
Integer
Decimal
Sign
digit
Exist
1
Procedure
Move the cursor with [FEED] or [RESTART].
Press [FEED] + [RESTART] to move to the
ON
"Set Parameters" screen.
OFF
Move the cursor with [FEED] or [RESTART].
Press [FEED] + [RESTART] to move to the
"Set Parameters" screen.
Pre-peeling fine adjustment can be set to
"-2.5mm-+ 9.9mm".
Press [FEED] + [RESTART] to move to the
"Pre-Peel Off" screen.
Press [RESTART] to move to the "Pre-Peel
Off" screen.
Press [PAUSE] to move to the "Set
Parameters" screen.
Feeds only the distance obtained by adding
the fine adjustment value set from the
pre-peeling distance (6.0 mm).
Move back to "Pre-peeling fine adjustment
setting screen" after back-feeding the distance
fed in the test mode with [RESTART].
The screen does not move when [FEED] is
pressed.
75
Unit of
0-padding
place
measure
1
None
mm