Print method
Sensor type
Speed
Print count
Issue mode
<< COUNTER >>
Item
TOTAL FEED
FEED
FEED1 to FEED4
PRINT
PRINT1 to PRINT4
CUT
RIBBON
232C ERR
SYSTEM ERR
POWER FAIL
Description
Range
Counting condition
[Description] Total label distance covered (cannot be cleared)
[Range] 0.0 to 3200.0 km
[Counting condition] Counted when the media feed motor is driven to feed or
print the media. (Reverse feed is also counted.)
When the power is turned off, the media distance of 50.0 cm or less may be
rounded down when backed up.
[Description] Label distance covered
[Range] 0.0 to 3200.0 km
[Counting condition] Counted when the media feed motor is driven to feed or
print the media. (Reverse feed is also counted.)
When the power is turned off, the media distance of 50.0 cm or less may be
rounded down when backed up.
[Description] History of last 4 label distances
[Range] 0.0 to 3200.0 km
[Counting condition] When the maintenance counter is RAM-cleared, the label
distance covered is saved as FEED 1. At this time, data which were saved in
FEED 1, FEED 2 and FEED 3 are re-saved as FEED 2, FEED 3, and FEED 4,
respectively.
[Description] Print distance
[Range] 0.0 to 200.0 km
[Counting condition] Counted while printing. (Reverse feed is not counted.)
[Description] History of last 4 print distances
[Range] 0.0 to 3200.0 km
[Counting condition] When the maintenance counter is RAM-cleared, the print
distance is saved as PRINT 1. At this time, data which were saved in PRINT 1,
PRINT 2 and PRINT 3 are re-saved as PRINT 2, PRINT 3, and PRINT 4,
respectively.
[Description] Cut count
[Range] 0 to 1000000
[Counting condition] Every cut operation is counted.
The cut count is saved every 1 cut operations.
[Description] Ribbon motor drive time
[Range] 0 to 2000 hours
[Counting condition] Counted when the ribbon motor is driven while media feed
or printing. (Reverse feed is also counted.)
When the power is turned off, drive time of 10 seconds or less is rounded
down when backed up.
[Description] The number of times an RS-232C hardware error occurred
[Range] 0 to 255
[Counting condition] Counted when a parity error, overrun error or framing
error occurs.
[Description] The number of times a system error occurred
[Range] 0 to 15
[Counting condition] Counted when a system error occurs.
[Description] The number of times a momentary power interruption occurred
[Range] 0 to 15
[Counting condition] Counted when a momentary power interruption occurs.
46