Raystar 112, 105, Apelco 182 And 182Xt - Raymarine RL70C Owner's Handbook Manual

Hsb series lcd display
Table of Contents

Advertisement

182

Raystar 112, 105, Apelco 182 and 182XT

In order to connect your GPS to your Chartplotter or Combined Radar/
Chartplotter, you must first cut off the 6-pin connector and strip back the
insulation on all the wires. Connect to the Auxiliary Junction Box as shown in
the first illustration below.
To connect your Differential Beacon Receiver, you must cut off the 5-pin
connector (Raytheon and Apelco versions), strip back the insulation on all the
wires and connect to the Auxiliary Junction Box as shown in the second
illustration below.
CAUTION
Ensure the correct polarity of the 12 V supply before applying display or
SeaTalk power. It is recommended that a multimeter is used to check the
connections.
To Display Unit
SeaTalk Socket
Black
12V
Power
Supply
Red
(fused)
To Display Unit
SeaTalk Socket
Black
12V
Power
Supply
Red
(fused)
HSB Series LCD Display
Black
Red
From
Yellow
GPS
Green
sensor
White
Brown
D4294-3
Black
Red
From
Yellow
GPS
sensor
Green
White
Brown
Black
Red
From
the
Yellow
DBR
White
Green
D4295-3