Note: The slide control controls the input gain of the microphone, not the output level of
the speaker. To control the output level of the speaker, use the
trol for this station on the Nyquist server. If this device is in Standalone mode, the output
level can be controlled using the
tings page.
Intercom Tuning
Presets

Setting the Channel Level

The channel level control is a channel fader, which is adjusted in 1
controls the microphone volume level for the channel. The channel levels can range from
60 to +12 dB. If you place the mouse over the fader, the numerical value of the level
appears.

Adjusting Volume Levels

The channel fader control can be used to adjust the channel's microphone volume level in
1-dB increments between
of the channel signal can be viewed on the
between
60 and 0 dB.
To adjust the channel volume level:
1
On the appliance Web UI's main page, select DSP.
2
Use the channel's fader to adjust the volume level.

Knob Adjustments

Many DSP controls use knobs to adjust one or more settings. The value of a knob can be
adjusted in one of two ways:
Intercom Cut Level
Table 7. DSP Features
Allows you to specify settings used in intercom calls and
when the intercom switches between send and receive
modes.
Allows you to use preset DSP settings for the selected
speaker type.
Note: Selecting the Speaker Type to match the installed speaker will
help eliminate feedback and noise from the device's microphone.
60 and +12 dB. The overall adjusted microphone volume level
OUT
Intercom Cut Level
control on the Configuration Set-
dB increments and
-
VU meter, marked in 2-dB increments
con-