Pre-Operation Inspection; Checking Engine Oil - Shindaiwa DG50MKM-P Owner's And Operator's Manual

Diesel engine generator
Table of Contents

Advertisement

(3) Earth leakage circuit breaker (ELCB) has activated
When the ELCB has activated, repair the leakage point and restore it by the following
procedure.
(Overload happens when the breaker activates but the Earth leakage breaker does
not activate.)
Turn the 3-Phase ELCB to ON to restore.
Turn the 1-Phase ELCB to ON to restore.
By the above procedure, you can reset the ELCB to ON positions.

8. Pre-Operation Inspection

WARNING : ELECTRIC SHOCK/INJURY
 Before performing any equipment check or maintenance, stop the engine,
and turn the Power Switch to the OFF position.
 Close all doors and place locks during operating this equipment, to avoid
injuries by unintentionally touching cooling fan and fan belt.
CAUTION : BURNS
 Do not touch the engine and surrounding components immediately after
stopping the equipment, while temperature can reach extremely high.
CAUTION : FIRE
 Always be sure to wipe up any spilled fuel or oil.

8-1. Checking Engine Oil

To check the engine oil, keep the equipment in leveled position, remove the oil level
indicator and wipe so that no oil remains, and then re-insert the dipstick fully. Prior to
starting the engine, make sure to fill the engine oil through the oil filler until it reaches
the MAX line.
< Note >
 Wait approximately five minutes or more
after stopping the engine or adding oil
before checking the oil level again.
 An accurate oil level reading cannot be
obtained if the generator is not placed in
leveled position.
 Do not overfill with oil to avoid engine
damage.
(1) Types of Engine Oil
Use only API service-type CF class.
Oil Level
Indicator
Oil Filler
18
Oil Level
MIN
MAX
Indicator
Not
Too
OK
Enough
Much

Advertisement