Shindaiwa DG50MKM-P Owner's And Operator's Manual page 36

Diesel engine generator
Table of Contents

Advertisement

(9) Elimination of carbon in the exhaust pipe line and muffler
WARNING : EXHAUST GAS POISONING
 Do not operate the generator in poorly ventilated areas such as an indoors
or tunnels, as the exhaust gas of the engine contains substances that are
harmful to human health.
 Do not direct exhaust fumes at bystanders or buildings.
WARNING : INJURY
 Always be sure to check that the breakers on load side and switches for
any equipment using the generator are at OFF before turning the breaker
to ON. Also be sure to advise personnel on the load side that power will be
turned on before operating the breaker.
 Close all doors and lock them during operation.
CAUTION : FIRE
 Do not bring flammable items (such as fuel, gas and paint) or items that
are highly combustible near the generator as the muffler, exhaust gas and
other parts become extremely hot.
 Position this generator 1 m or more from walls or other hindrances,
and on a level surface.
CAUTION : INJURY
 Do not operate the generator if it has been modified or any parts have
been removed.
 Position the generator on a level stable surface so that it cannot slide or
move in any manner.
 Before starting operation, always be sure to turn off all switches of
equipment being used and all breakers to OFF.
Clean
Accumulation of carbon (soot, unburned fuel) in the exhaust pipe line and muffler could
cause only a system derates or an engine fault occurs. To destroy the soot and unburned
fuel, run the unit at rated power for some period of time until the exhaust gas become
mostly colorless every 250 hours operation time. The carbon will be easier to be generated
when the unit operates at less then 30% of rated power. In this case, perform the above
procedures at shorter interval time.
< Note >
 When the unit operates at rated power, accumulation of carbon in the exhaust pipe line
and muffler might be lead to back fire incident. Do not bring flammable items that are
highly combustible near the generator.
Every 250 hours
33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dg50mkm-p/anz