Transporting/Installing; Transport Procedures - Shindaiwa DG50MKM-P Owner's And Operator's Manual

Diesel engine generator
Table of Contents

Advertisement

< Note >
 When disconnecting piping from the external tank, turn the lever to the "A" side, and
attach the bundled plug (R3/8")to the external tank fuel inlet/return.
(2) If using an external fuel tank
Connect hoses from the external fuel tank to the
external fuel inlet and the external fuel return. Change
the lever of the 3way fuel valve to the "B" side to
supply fuel from the external tank.
(Refer to "9-5. Connecting with External Fuel Tank" for
corresponding procedures.)

6. Transporting/Installing

6-1. Transport Procedures

WARNING : INJURY
 Do not lift up the unit using tie down. Use of such could result in the generator falling.
 No persons should be under a lifted generator.
CAUTION : INJURY
 Always be sure to use lifting hooks when lifting up the generator, and raise it
slowly at a completely vertical angle.
 Personnel performing lifting work must wear protective gear such as helmets,
safety shoes and gloves.
 Do not move the generator during operation.
(1) Lifting Procedures
Always be sure to use lifting hooks when lifting up the generator, and raise it slowly
at a completely vertical angle.
(2) Transport
When transporting this generator, tie rope to the left and right tie downs, and
securely fix the generator.
Lifting
Hook
< Note >
 Handle this generator with great care when raising, lowering and transporting. Rough
handling of generator can result in damage or malfunction.
 Before transporting, check the inside of the spill containment and drain any accumulated
liquid.
External Fuel
Inlet
Tie-Down
14
3Way Fuel
Valve
External Fuel
Return

Advertisement