ESIE17-08
|
Part 5. Appendix
5.5.2. Outdoor unit
a. Heat exchanger
b. Internal service port
c. Switch box cooling
d. Check valve (not visible, located behind compressor)
e. Liquid receiver
f. Stop valve with service port (liquid)
g. Stop valve with service port (gas)
h. Cable tie mountings (to fix the field wiring with cable ties to ensure stress relief)
i. Compressor accumulator
Page 126
R32 Sky-Air RZAG-M
Figure 5-9: Components overview - outdoor unit 71
A1P
Printed circuit board (main)
M1C
Motor (compressor)
M1F
Motor (fan)
S1PH-A
Automatic high pressure switch
(not visible, see
S1PL
Low pressure switch
(not visible, see
X1M
Terminal (communication and power supply)
Y1E
Electronic expansion valve
Y3E
Electronic expansion valve
Y1S
Solenoid valve (4-way valve)
Y2S
Solenoid valve
5.5. Component overview of unit
figure 3-23 "Removing high pressure switch" on page
figure 3-24 "Removing low pressure switch" on page
89)
91)
15/11/18
|