Clearances

The clearances listed below are minimum distances unless otherwise stated.
A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance
that this fireplace and flue system be installed only in accordance with these instructions.
Caution Requirements
The top, back and sides of the fireplace are defined by
standoffs. The metal ends of the standoff may NOT be
recessed into combustible construction.
Clearance:
A: Mantel Height (min.)
B: Sidewall (on one side)
C: Ceiling
(room and/or alcove)
D: Mantel Depth (max.)
E: Alcove Width
F: Alcove Depth
G: From Floor
Note:
D
A
G
Dimension
Measured From:
254 mm
Top of Fireplace Opening/Hot Air Outlet
152 mm
Side of Fireplace Opening/Hot Air Outlet
1162 mm
Top of Fireplace Opening/Hot Air Outlet
730mm Above Fireplace Opening/Hot
305mm
Air Outlet
1524 mm
Sidewall to Sidewall (Minimum)
914 mm
Front to Back Wall (Maximum)
617 mm
Top of Fireplace Opening/Hot Air Outlet
0
No hearth required
F
B
E
Installed Close
to Floor
F
Fire hazard is an extreme risk
if these clearances (air space) to combustible materials are not
adhered to. It is of greatest importance that this fireplace and flue
system be installed only in accordance with these instructions.
E
Alcove
WARNING
Flue Clearances to Combustibles
Horizontal - Top
Horizontal - Side
Horizontal - Bottom
Vertical
IMPORTANT: If installing a television above
this appliance, the television must be either
fully recessed into the wall above the fireplace
and or have a mantle below the television. If the
television is left unprotected, the extreme heat
being emitted from this appliance will result
in damage to the television. See clearance
requirements for both mantle (page 9) and
or enclosing the top of the appliance (page
11 (D) dimension).
Installed close
to ceiling.
Greenfire® GF1500L-2 Gas Fireplace
installation
76mm
51mm
51mm
51mm
|
9