Clearances for Combustible Finishing with Mantel

Due to the extreme heat this fireplace emits, the mantel clearances are critical.
Combustible finishing and mantel clearances are shown in the diagram
on the right. Finishing Trim must be used with combustible finishing.
Note: Maximum combustible finishing material thickness is 19mm
measured from the front of the fireplace opening. If total
finishing material is greater than 19mm, non-combustible
must be used.
Note: Ensure the paint that is used on the mantel and the facing is
"high quality" or the paint may discolour.
Note: Combustible mantel starts at 796mm (618mm + 178mm) from
unit base.
Important:

Combustible Mantel Leg Clearances

Mantel leg & combustible finishing clearances as per diagram:
Combustible
MANTEL LEG
MANTEL LEG
Allowable mantel
Allowable mantel
leg projection
leg projection
13mm Gap
38mm
38mm
181mm
181mm
254mm
254mm
330mm
330mm
(305mm)
(152mm)
(576 mm)
(322 mm)
(372 mm)
(470 mm)
(0)
To unit base
(630 mm)
13mm Gap
181mm
254mm
330mm
installation
(305mm)
Combustible Material
(200mm)
Combustible Stud
(On Edge)
(100mm)
Combustible facing
(min. 10mm- max. 19mm)
Nailing Flange
(297 mm)
(241mm)
Top of
Fireplace
Opening
Combustible
MANTEL LEG
38mm
Greenfire® GF1500L-2 Gas Fireplace
Allowable mantel
leg projection
|
13