maintenance
Troubleshooting Guide________________
Troubleshooting Guide
Unit ignites, main burner becomes
unstable, flame lifts off burner, unit
goes into lockout
Fan operates but no ignition
sequence (no spark)
Carbon build up on
glass/media/logs
58
|
Greenfire® GF1500L-2 Gas Fireplace
Incorrect burner pressure
settings
Flue blocked, Incorrect flue
installation or flue joints not
sealed
Burner aeration not correctly
adjusted
Log set incorrectly installed
Flue Restrictor not set
correctly
Unit ignition pack gone into
lockout
Burner cracked
Log set / media incorrectly
installed
Aeration setting too far closed
Aeration blocked
Flue restrictor not set
correctly
Partial blockage in flue
Adjust burner pressure to correct
setting (See Data plate)
Clear blocked flue, install flue
correctly and seal all flue joints
Adjust burner aeration
(See Unit Manual)
Install log set as per Owner's
Manual
Adjust Flue restrictor (See unit
manual)
Reset ignition pack by depressing
black reset button while unit
controls are in the "ON" position
(fan running)
Replace burner
Install log set / media as per
owner's manual
Set aeration as per owner's
manual
Clean blockage at aeration
shutter
Adjust flue restrictor as per
owner's manual
Clear blocked flue

Advertisement