2. Bend the retaining lug on the switch to the side.
3. Replace the switch.
5.2.12

Fully Integrated (VI) Lock with Door Contact Switch Removal

1. Door outer panel removal (5.2.3).
2. Fascia panel removal (5.2.4).
3. Remove the screws from the sides of the door inner panel.
4. Remove the lock retaining screw.
5. Remove the holder with electronic unit.
6. Remove the lock with door contact switch.
7. Disconnect the door contact switch plug connections.
5.2.13
Door lock emergency release – Activate (Fully Integrated)
1. Remove outer door panel (5.2.3).
Figure 5-16: Door lock emergency release.
2. To return the locking latch into the right position, push on the emergency release
with a screwdriver, see figure 5-16, Pos.1