Excella Series - G2670; G2670 Programming Mode - Miele G2000 Technical Information

Hide thumbs Also See for G2000:
Table of Contents

Advertisement

G1000 / G2000 Dishwashers
V17. 5N1, M6, wash sequence with bottom spray arm sensor (mini program):
This starts with 30 sec. drainage, which begins with pulsed priming
(2 sec. on / 2 sec. off). The water inlet valve is then activated (on
models with and without slide shutter) until 5.4 l has been taken in. At the same
time the water inlet valve is activated, the slide shutter is set to the middle
spray arm position. The circulation pump with switched auxiliary winding is then
operated. After 2 sec. the slide shutter is set to the top/bottom spray arm
position. If a spray arm fault is registered during circulation pump operation, the
pump is switched off after 60 sec., otherwise it operates for a further 120 sec.
6.5.2
Excella Series – G2670
6.5.2.1

G2670 Programming Mode

Initial requirements
1. Open the door.
2. Switch off the machine.
Accessing
1. Press and hold the C (Clear) Button
2. Switch on the machine.
3. Release the C (Clear) button.
4. When display lights up, immediately press and release the C (Clear) button 5
times and at the 5 time hold for 4 seconds.
Acknowledgement Indicator
Successful accessing of the Service Dept. programming mode is indicated by LEDs,
which are all off and the indication Service Programming shown in the right display
The display shows two parameters at the same time.
Use the cursor button to scroll the display.
Options
Refer to Tables: 6-50 through 6-52.
Note
Some of the following parameters can also be programmed via the
Settings menu.
183
Technical Information

Advertisement

Table of Contents
loading

Table of Contents