Miele G2000 Technical Information page 212

Hide thumbs Also See for G2000:
Table of Contents

Advertisement

Technical Information
5. Check the Flow meter B3/4 for too few pulses (F13), no pulses (F12) or sluggish
movement (F19) by performing the following steps:
a. Remove the left side panel (5.1.1).
b. Check that the plate with the reed switch on the flow meter is
c. Check that the reed switch connection plug is seated correctly.
d. While in operation:
Fault F19 will be displayed if the check to test the sluggish movement of the
flowmeter (impeller counter) during the water intake is not successful.
Start rinse block water intake:
Item a: Test time for one liter.
Item 1: Sufficient normal water intake time.
Item 2: Extended water intake time required.
Item 3: After a water intake of 1 liter, it becomes apparent that neither the
normal nor the extended water intake time will be sufficient. Therefore the
test routine is started.
Figure 6-4: F19 - Start rinse block water intake
seated correctly.
If F12, F13 or F19 is displayed, disconnect the electrical connector from the
electronic board and hook up a multi meter set for continuity.
If no pulses are delivered, take a magnet and pass it over the reed switch. If a
pulse is delivered, replace the water diverter. If no pulse is delivered, replace
the reed switch.
If pulses are delivered. Connect the electrical connector to the electronic
board, clear the fault and operate the appliance. If an F12 is displayed
replace the electronic board.
G1000 / G2000 Dishwashers