Miele G2000 Technical Information page 176

Hide thumbs Also See for G2000:
Table of Contents

Advertisement

Technical Information
Function
Pos. 20:
Resetting
standard
settings
Pos. 21:
Wash/Final
rinse
temperature
modification
(from software
version ID no.
984).
Main wash
Final rinse
Pos. 23: Water
quantity normal
/ increased
Pos. 24:
Sensor
softener
activation /
deactivation,
water hardness
manual setting
Pos. 25:
Program
running time
reduction (from
software
version ID no.
984)
Pos. 26:
Second interim
rinse selection
(from software
version ID no.
984)
Table 6-47: G2630 Programming Mode Options (Cont. From Table 6-46) (Cont. on Table 6-48)
Programming
Use the cursor buttons as
appropriate to select Factory
default, then press the OK button.
Use the cursor buttons to make the
desired setting.
Use the cursor buttons as
appropriate to select
Temperatures, then press the OK
button. Use the cursor buttons to
make the desired setting.
Use the cursor buttons to select the
desired option.
Use the cursor buttons to select the
desired option.
Use the cursor buttons as
appropriate to select Water plus,
then press the OK button. Use the
cursor buttons to make the desired
setting.
Use the cursor buttons as
appropriate to select Water
hardness, then press the OK
button. Use the cursor buttons to
make the desired setting.
Use the cursor buttons as
appropriate to select Shorten the
program, then press the OK
button. Use the cursor buttons to
make the desired setting.
Use the cursor buttons as
nd
appropriate to select 2
rinse, then press the OK button.
Use the cursor buttons to make the
desired setting.
176
G1000 / G2000 Dishwashers
The display shows the option
Reset. If it is selected, all
parameters that can be
modified by the customer
(extras and settings) will be
reset to the standard settings.
The display shows the options
Main wash and Final rinse.
This increases the main wash
or final rinse temperature with a
running time extension.
The display shows the options
Normal and Increased
The display shows the options
Normal and Increased
The display shows the options
Normal and Increased
Automatic = sensor softener
activated. Alternatively the on-
site water hardness can be
directly selected. Setting range:
1°d to 70°d (°d = Degree of
German hardness). See Table
6-2.
The display shows the options
On and Off (standard setting).
This offers a program-
dependent running time
reduction by reducing
temperatures and/or canceling
holding times.
The display shows the options
interim
On and Off (standard setting)
Display