8.9

Technical specifications of the interfaces

Observe the information in "Applicability of technical specifications (Page 82)" and use only
original connections of the I/O to be connected.
DisplayPort
Keyboard
Mouse
USB
Ethernet
COM1, COM2 (optional)
Free slot for PCIe expansion cards (see Bus board (Page 109))
1
2
3
4
5
SIMATIC IPC PX-39A
Operating Instructions, 08/2022, A5E51699601-AA
1
2
An analog monitor can be used with an adapter cable (optional).
For unambiguous labeling, the Ethernet interfaces are numbered on the enclosure. The numbering
by the operating system can differ.
No teaming with iAMT
When using iAMT, the X1 P1 interface must be used to connect to remote maintenance.
Only possible with ports X1 P1 and X2 P1
8.9 Technical specifications of the interfaces
2 x connection of DisplayPort monitor
USB support
USB support
4 × USB 3.2 Gen 2 type A, high current, backward compatible
4 × Ethernet interface (RJ45), 10/100/1000 Mbps
1 x Ethernet 1: Intel® Jacksonville i219-LM; iAMT-capable
1 x Ethernet 2: Intel® Springville i210-IT
2 x Ethernet 3, 4: Intel® EC 1000S
Wake on LAN, Remote Boot and the following Teaming modes are sup-
ported
:
5
Adapter Fault Tolerance (AFT)
Adaptive Load Balancing (ALB)
IEEE 802.3ad Dynamic Link Aggregation (DLA)
Static Link Aggregation (SLA)
Switch Fault Tolerance (SFT)
RS232, 115 kbps max., 9-pin SUB-D, male
Technical specifications
3, 4