5.3

Monitoring of the device

5.3.1

Monitoring functions

You can monitor the following device functions with the SIMATIC IPC DiagBase or SIMATIC IPC
DiagMonitor software:
Monitoring
Temperature monitor-
ing
Watchdog
Voltage monitoring
Drive monitoring
Software for device monitoring
You can find information on the monitoring software and its documentation under:
• SIMATIC IPC DiagBase (Page 58) for monitoring and alarming locally on the device
• SIMATIC IPC DiagMonitor (Page 58) for monitoring and alarming via network
SIMATIC IPC PX-39A
Operating Instructions, 08/2022, A5E51699601-AA
Description
Monitoring for temperature high and low limits as
well as cable breaks of the temperature sensors
Temperature sensors record the temperature at criti-
cal device points, e.g. at the processor.
The temperature thresholds are defined for the indi-
vidual temperature sensors.
With SIMATIC IPC DiagBase or SIMATIC IPC DiagMoni-
tor, actions are triggered when the temperature
thresholds are exceeded.
Monitoring of the system status and message to de-
termine if a station is still operational
If the watchdog is not addressed within a configured
monitoring time, a watchdog alarm is output.
A change to the monitoring time is effective immedi-
ately.
Monitoring the charge status of the backup battery
(CMOS)
When the first warning threshold is reached, the
backup battery will run for at least one more month.
Determination of the status of the drives (SSD) with
SMART functionality, also in RAID systems (RAID sta-
tus)
Operating the device
5.3 Monitoring of the device
Status displays and actions
Temperature alarm is generated.
Depending on the setting, the following
actions are triggered:
Reset on: Hardware reset is per-
formed
Reset off: No action is performed
The device is restarted
The device is shut down
An alarm is generated in the event
of a critical or faulty state.
SMART status of the hard disks
For example, the following states
are displayed in a RAID group:
"Normal", "OK", "Degraded", error
"Rebuild", rebuilding