Technical Specifications Of The Interfaces - Siemens SIMATIC IPC PX-32A Operating Instructions Manual

Table of Contents

Advertisement

8.9

Technical specifications of the interfaces

Observe the information in "Applicability of technical specifications (Page 63)" and use only
original connections of the I/O to be connected.
DisplayPort
Keyboard
Mouse
USB
Ethernet
COM1, COM2
COM3, COM4 (optional)
1
2
3
4
5
SIMATIC IPC PX-32A
Operating Instructions, 09/2023, A5E53092695-AA
1
2
An analog monitor can be used with an adapter cable (optional).
For unambiguous labeling, the Ethernet interfaces are numbered on the enclosure. The number-
ing by the operating system can differ.
No teaming with iAMT
When using iAMT, the X1 P1 interface must be used to connect to remote maintenance.
Only possible with ports X1 P1 and X2 P1
8.9 Technical specifications of the interfaces
2 x connection of DisplayPort monitor
USB support
USB support
4 × USB 3.2 Gen 2 type A, high current, backward compatible
2 × Ethernet interface (RJ45), 10/100/1000 Mbps
1 x Ethernet 1: Intel® Jacksonville i219-LM; iAMT-capable
1 x Ethernet 2: Intel® Springville i210-IT
Wake on LAN, Remote Boot and the following Teaming modes are
supported
:
5
Adapter Fault Tolerance (AFT)
Adaptive Load Balancing (ALB)
IEEE 802.3ad Dynamic Link Aggregation (DLA)
Static Link Aggregation (SLA)
Switch Fault Tolerance (SFT)
RS232/RS422/RS485, 115 kbps max., 9-pin D-sub, male
RS232, 115 kbps max., 9-pin D-sub, male