8.5

Ambient conditions

See the note in "Applicability of technical specifications (Page 82)".
NOTICE
Temperature - during operation
When operating with maximum expansion and maximum application load, the temperature
in the PCIe expansion card area may increase up to 25 °C compared to the ambient
temperature, depending on the device mounting position.
Climatic ambient conditions
Temperature
- Operation
- Storage/transport
- Gradient
Relative humidity
- Operation
- Storage/transport
SIMATIC IPC PX-39A
Operating Instructions, 08/2022, A5E51699601-AA
Landscape format - horizontal:
19" display:
Operation with two M.2 NVMe SSDs:
With 1 expansion card
(max. load 8 W): 0 to +45 °C
Without expansion card: 0 to +50 °C
15"/22"/24" display:
Operation with two M.2 NVMe SSDs:
With 1 expansion card
(max. load 8 W): 0 to +40 °C
Without expansion card: 0 to +45 °C
Horizontal format - inclined max. ± 45°:
19" display:
Operation with two M.2 NVMe SSDs:
With 1 expansion card
(max. load 8 W): 0 to +45 °C
15"/22"/24" display:
Operation with two M.2 NVMe SSDs:
With 1 expansion card
(max. load 8 W): 0 to +40 °C
Portrait format - vertical:
15"/19"/22"/24" display:
Operation with two M.2 NVMe SSDs:
With 1 expansion card
(max. load 8 W): 0 to +40 °C
-20 to +60 °C
max. 10 °C/h in operation, 20° C/h storage, no condensation
tested to IEC 60068-2-78, IEC 60068-2-30
Temperature 30 °C, relative humidity 85%;
Permitted range: 0 to 31 °C: 5 ... 80%; decreasing linearly to 5 ...
25% at 55 °C
Temperature 25 °C - 55 °C, relative humidity 95%
Technical specifications
8.5 Ambient conditions