Esp Curve: Outdoor Unit - Daikin EBLA04E2V3 Installer's Reference Manual

Hide thumbs Also See for EBLA04E2V3:
Table of Contents

Advertisement

17.3 ESP curve: Outdoor unit

EBLA04~08E2V3+E23V3 + EDLA04~08E2V3+E23V3
Daikin Altherma 3 M
4P685228-1A – 2022.05
Note: A flow error will occur when the minimum water flow rate is not reached.
A (kPa)
80
70
60
50
40
30
C
D E
20
10
0
0
5
10
A External static pressure
B Water flow rate
C Minimum flow during normal operation
D Minimum flow during Cooling operation
E Minimum flow during Defrost and Backup heater operation
With built-in BUH:
A (kPa)
80
70
60
50
40
30
C
D E
20
10
0
5
10
0
A External static pressure
B Water flow rate
C Minimum flow during normal operation
D Minimum flow during Cooling operation
E Minimum flow during Defrost and Backup heater operation
Notes:
Selecting a flow outside the operating area can damage the unit or cause the unit
to malfunction. See also the minimum and maximum allowed water flow range in
the technical specification.
Water quality must be according to EU directive 2020/2184.
15
20
25
30
15
20
25
30
17
Technical data
|
35
40
B
(l/min)
4D139364
35
40
B ( l/min)
4D139365
Installer reference guide