To Connect The Main Power Supply - Daikin EBLA04E2V3 Installer's Reference Manual

Hide thumbs Also See for EBLA04E2V3:
Table of Contents

Advertisement

9
|
Electrical installation

9.2.2 To connect the main power supply

Installer reference guide
96
a
b
a High voltage options
b Low voltage options
c Power supply for backup heater (in case of unit with integrated backup heater)
Wiring for backup heater kit (in case of external backup heater kit)
d Unit power supply
4 Connect the wires to the appropriate terminals, and fix the cables with cable
ties.
This topic describes 2 possible ways to connect the main power supply:
In case of normal kWh rate power supply
In case of preferential kWh rate power supply
In case of normal kWh rate power supply
Normal kWh rate
power supply
1 Access the electrical connections. See
to the outdoor
unit" [
2 Connect as follows:
180°
c
d
Wires: 1N+GND
Maximum running current: Refer to name plate on
unit.
"9.2.1 To connect the electrical wiring
4
 95].
1N~
Q1DI
N N
L N N N PE
N
N N N N N N N N N N N N N N N
N
N N
1N~, 50 Hz,
220-240 V AC
1N~
L N
N
X1M
EBLA04~08E2V3+E23V3 + EDLA04~08E2V3+E23V3
Daikin Altherma 3 M
4P685228-1A – 2022.05

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents