Application Guidelines; Overview: Application Guidelines - Daikin EBLA04E2V3 Installer's Reference Manual

Hide thumbs Also See for EBLA04E2V3:
Table of Contents

Advertisement

6
|

Application guidelines

6 Application guidelines
In this chapter

6.1 Overview: Application guidelines

Installer reference guide
26
INFORMATION
Cooling is only applicable in case of reversible models.
6.1
Overview: Application guidelines ...........................................................................................................................................
6.2
Setting up the space heating/cooling system ........................................................................................................................
6.2.1
Single room.............................................................................................................................................................
6.2.2
Multiple rooms - One LWT zone ...........................................................................................................................
6.2.3
Multiple rooms - Two LWT zones .........................................................................................................................
6.3
Setting up an auxiliary heat source for space heating...........................................................................................................
6.4
Setting up the domestic hot water tank ................................................................................................................................
6.4.1
System layout - Standalone DHW tank .................................................................................................................
6.4.2
Selecting the volume and desired temperature for the DHW tank......................................................................
6.4.3
Setup and configuration - DHW tank ....................................................................................................................
6.4.4
DHW pump for instant hot water ..........................................................................................................................
6.4.5
DHW pump for disinfection ...................................................................................................................................
6.4.6
DHW pump for tank preheating ............................................................................................................................
6.5
Setting up the energy metering .............................................................................................................................................
6.5.1
Produced heat ........................................................................................................................................................
6.5.2
Consumed energy ..................................................................................................................................................
6.5.3
Power supply layouts with power meters .............................................................................................................
6.6
Setting up the power consumption control...........................................................................................................................
6.6.1
Permanent power limitation..................................................................................................................................
6.6.2
Power limitation activated by digital inputs ..........................................................................................................
6.6.3
Power limitation process .......................................................................................................................................
6.6.4
BBR16 power limitation .........................................................................................................................................
6.7
Setting up an external temperature sensor...........................................................................................................................
The purpose of the application guidelines is to give a glance of the possibilities of
the heat pump system.
NOTICE
The illustrations in the application guidelines are meant for reference only, and
are NOT to be used as detailed hydraulic diagrams. The detailed hydraulic
dimensioning and balancing are NOT shown, and are the responsibility of the
installer.
For more information about the configuration settings to optimize heat  pump
operation, see "11 Configuration" [
This chapter contains application guidelines for:
Setting up the space heating/cooling system
Setting up an auxiliary heat source for space heating
Setting up the domestic hot water tank
Setting up the energy metering
Setting up the power consumption control
Setting up an external temperature sensor
4
 123].
EBLA04~08E2V3+E23V3 + EDLA04~08E2V3+E23V3
26
27
28
32
36
40
43
43
43
45
45
46
47
48
48
48
49
54
54
55
56
57
58
Daikin Altherma 3 M
4P685228-1A - 2022.05

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents