5.2.2 Possible combinations of outdoor unit and domestic hot water tank

EBLA04~08E2V3+E23V3 + EDLA04~08E2V3+E23V3
Daikin Altherma 3 M
4P685228-1A – 2022.05
Control the system via a smartphone app.
Use the system in various Smart Grid applications.
For installation instructions, see the installation manual of the LAN adapter.
Combination table
Outdoor unit
EKHWS*D*
EBLA04~08
EDLA04~08
(a)
When using a third-party tank, make sure it complies with the minimum requirements (see
"Third-party tank
requirements" [
Third-party tank requirements
In case of a third-party tank, the tank shall adhere to the following requirements:
The heat exchanger coil of the tank is ≥1.05 m² and ≤3.7 m².
The tank thermistor must be located above the heat exchanger coil.
The booster heater must be located above the heat exchanger coil.
NOTICE
Performance. Performance data for third-party tanks CANNOT be provided, and
performance CANNOT be guaranteed.
Can insert a thermistor.
a
b
Use EKHY3PART.
a Outdoor unit
b Tank
For more detailed installation instructions, see the installation manual of the
connection kit and the addendum book for optional equipment.
5
|
Domestic hot water tank
EKHWSU*D*
O
O
O
O
4
 25]).
If you have a tank in which you...
About the units and options
EKHWP*
Third-party
O
O
CANNOT insert a thermistor.
a
b
Use EKHY3PART2.
Installer reference guide
tank
(a)
O
(a)
O
25