16.7 ESP curve: Indoor unit

EPRA14~18D + ETVH16SU18+23E
Daikin Altherma 3 H HT F
4P644738-1D – 2023.10
Note: A flow error will occur when the minimum water flow rate is not reached.
A (kPa)
120
110
100
90
80
70
60
50
40
30
20
10
0
0
5
10
15
D
E
A External static pressure in the space heating/cooling circuit
B Water flow rate through the unit in the space heating/cooling circuit
C Operation range
D Minimum water flow during normal operation
E Minimum water flow during backup heater operation
F1 Minimum water flow during defrost operation (for E models)
F2 Minimum water flow during defrost operation (for E7 models)
Notes:
Selecting a flow outside the operating area can damage the unit or cause the unit
to malfunction. See also the minimum and maximum allowed water flow range in
the technical specifications.
Make sure water quality complies with EU directive 2020/2184.