To Connect The Domestic Hot Water Pump; To Connect The Alarm Output - Daikin EBLA04E2V3 Installer's Reference Manual

Hide thumbs Also See for EBLA04E2V3:
Table of Contents

Advertisement

9
|
Electrical installation

9.2.8 To connect the domestic hot water pump

9.2.9 To connect the alarm output

Installer reference guide
112
Wires: (2+GND)×0.75 mm²
DHW pump output. Maximum load: 2 A (inrush), 230 V AC, 1 A
(continuous)
[9.2.2] DHW pump
[9.2.3] DHW pump schedule
1 Access the electrical connections. See
to the outdoor
unit" [
2 Connect the domestic hot water pump cable to the appropriate terminals as
shown in the illustration below.
180°
3 Fix the cable with cable ties to the cable tie mountings.
Wires: (2+1)×0.75 mm²
Maximum load: 0.3 A, 250 V AC
[9.D] Alarm output
1 Access the electrical connections. See
to the outdoor
unit" [
2 Connect the alarm output cable to the appropriate terminals as shown in the
illustration below.
"9.2.1 To connect the electrical wiring
4
 95].
X2M.1
M
M2P
1~
X2M.2
X2M
1
2
"9.2.1 To connect the electrical wiring
4
 95].
EBLA04~08E2V3+E23V3 + EDLA04~08E2V3+E23V3
Daikin Altherma 3 M
4P685228-1A – 2022.05