Unit detail
PMS
PWS
Qn HS
Qn Hi
Pn
6.3

Combining units and options

6.3.1

Possible combinations of outdoor unit, gas boiler and domestic hot water tank

System
Outdoor unit
Gas boiler
EJHA04AAV3
NHY2KOMB28AA
NHY2KOMB32AA
Third-party
(a)
Maximum tank set point is 60°C
(b)
Third-party tank is possible, but comfort cannot be guaranteed. See the minimum requirements for third-party tanks in
requirements" on
6.3.2

Possible options for the outdoor unit

User interface (EKRUHML*)
The user interface is required for operation, but has to be ordered
separately (mandatory option).
Following user interfaces are available:
▪ EKRUHML1 contains the following languages: English, French,
Dutch, Italian.
▪ EKRUHML2 contains the following languages: English, German,
Dutch, Italian.
For installation instructions, see
page 43.
Remote outdoor sensor (EKRSCA1)
By default the sensor inside the outdoor unit will be used to measure
the outdoor temperature.
As an option the remote outdoor sensor can be installed to measure
the outdoor temperature on another location (e.g. to avoid direct
sunlight) to have an improved system behaviour.
For installation instructions, see the installation manual of the remote
outdoor sensor and the addendum book for optional equipment.
Heat pump convector (FWXV)
For providing space heating, it is possible to use heat pump
convectors (FWXV).
For installation instructions, see the installation manual of the heat
pump convectors, and the addendum book for optional equipment.
EJHA04AAV3 + NHY2KOMB28+32AA
Daikin Altherma H Hybrid
4P556861-1A – 2019.05
Description
Information regarding electrical
power supply (Voltage, mains
frequency, elmax, IP-class)
Permissible overpressure in
space heating circuit
Permissible overpressure in
domestic hot water circuit
Input related to gross caloric
value in kilowatts
Input related to net caloric value
in kilowatts
Output in kilowatts
DHW tank
EKHWS*D*
Domestic hot water by tank.
EKHWP
Tank heated:
(b)
Third-party
▪ By outdoor unit only, or
▪ By gas boiler only
Instant domestic hot water by gas boiler ▪ By outdoor unit only, or
Instant domestic hot water by gas boiler ▪ By outdoor unit only, or
page 27.
"To connect the user interface"  on
6 About the units and options
Unit detail
DE, FR, GB, IT, NL
I2E(s), I2H, IIELL3P, II2H3P,
II2Esi3P
G20-20 mbar
G25-25 mbar
B23, ...., C93(x)
Tmax
IPX4D
Remark
DHW
▪ By outdoor unit only, or
▪ By gas boiler only, or
▪ By combination of outdoor unit and
gas boiler
(a)
▪ By gas boiler only, or
▪ By combination of outdoor unit and
gas boiler
▪ By gas boiler only (bivalent operation)
LAN adapter for smartphone control + Smart Grid applications
(BRP069A61)
You can install this LAN adapter to:
▪ Control the system via a smartphone app.
▪ Use the system in various Smart Grid applications.
For installation instructions, see the installation manual of the LAN
adapter and the addendum book for optional equipment.
LAN adapter for smartphone control (BRP069A62)
You can install this LAN adapter to control the system via a
smartphone app.
For installation instructions, see the installation manual of the LAN
adapter and the addendum book for optional equipment.
Room thermostat (EKRTWA, EKRTR1)
You can connect an optional room thermostat to the gas boiler. This
thermostat can either be wired (EKRTWA) or wireless (EKRTR1).
For installation instructions, see the installation manual of the room
thermostat and the addendum book for optional equipment.
Remote sensor for wireless thermostat (EKRTETS)
You can use a wireless indoor temperature sensor (EKRTETS) only
in combination with the wireless thermostat (EKRTR1).
For installation instructions, see the installation manual of the room
thermostat and addendum book for optional equipment.
Bottom plate heater (EKBPHT04JH)
▪ Prevents freeze-up of the bottom plate.
Description
Countries of Destination
(EN 437)
Approved unit categories
(EN 437)
Gas group and gas connection
pressure as set at the factory
(EN 437)
Approved flue gas category
(EN 15502)
Maximum flow temperature in °C
Electrical protection class
Space heating
"8.3.2 Water circuit
Installer reference guide
13