(12) Bleeding air from EGR cooler
Bleeding air
Every after coolant change
Loosen the air release plug of the EGR cooler in order to bleed air from within
1
the EGR and improve cooling performance.
2
When coolant flows out from the air release plug, tighten the air release plug.
Air bleeder plug tightening torque: 19.0 to 25.0 Nm ( 1.9 to 2.5 kgfm
/ 14.0 to 18.4 lbf・ft. )
Air Bleeder Plug
47