(2) Pilot Lamp
The pilot lamp is located on the generator control panel and indicates
whether or not the engine is running.
When the lamp is lit the engine is running.
When the lamp is not lit the engine is not running.
(3) Panel Light
The panel light is located on the generator control panel and is used to
illuminate the generator and engine control panels.
This light is turned on and off with the panel light toggle switch which is
also located on the generator control panel next to the panel light.
This light can only be energized when the engine is running.
Switches
(1) Starter Switch
STOP
RUN
PREHEAT
START
① ① ① ① Stop
When the switch is set to this position, all power will be off.
The switch must be set to this position to remove the key.
② ② ② ② Run / Preheat
The switch must be in this position during operation.
This position also is used to begin the engine preheat
cycle and to remove air from the fuel system.
< NOTE >
Do not leave the switch to this position, while the engine is
stopped. Otherwise the battery is discharged.
③ ③ ③ ③ Start
This position will allow user to start the engine. When the
key is released,the setting will automatically return to
<RUN> position.