3. Disassembly and Reassembly
3-2 (Step B) – Assy Control Box
WARNING
Disconnect power before servicing the range. Replace all panels before operating range. Failure to do so can result
in death or electrical shock.
WARNING
EXPLOSION, FIRE, AND ASPHYXIATION HAZARD
range. Replace all panels before operating range. Failure to do so can result in death or personal injury from
CAUTION
When you work on the gas range, be careful when handling sheet metal parts. Sharp edges may be present, and you
can cut yourself if you are not careful.
3
4
This document can not be used without Samsung's authorization.
2
1
3
3
5
1.
Remove 5 Knobs from the Assy Control
Box.
2.
Remove 2 screws next to the each 2 valve
shafts (Total 4 screw)
3.
Open the Door and Remove 3 screws from
the bottom of Assy Control Box.
3 3
4.
Lift the Assy Control Box slightly to
separate from the range.
(Assy Wire Main is still connected to the
Assy Display of Assy Control Box)
5.
Disconnect 3 wire connectors from the
Assy Display PCB.
6.
Remove the Assy Control Box from the
5
range.
5
19