ENGINE BLOCK HEATER AND
OPTIONAL INTERNAL BATTERY CHARGER
120 VAC INPUT RECEPTACLES
This generator comes equipped with an engine block
heater, and an internal battery charger is available as an
option. They are provided with electrical cords to connect
to a commercial power source.
The engine block heater and internal battery charger
both require 120 VAC in order to operate. A receptacle
(Figure 80) has been provided on the output terminal panel
to allow commercial power to be applied.
These receptacles will ONLY function when commercial
power has been supplied to them (Figure 80). When using
extension cords, refer to Table 6 for the correct size and
length.
Figure 80. Engine Block Heater And Optional Battery Charger
DCA25SSIU4FC8 60 HZ GENERATOR • OPERATION MANUAL — REV. #0 (08/23/22) — PAGE 47
When using the generator in hot climates there is no reason
to apply power to the engine block heater. However, if the
generator will be used in cold climates it is always a good
idea to apply power to the heater at all times.
If the generator will be used daily, the battery should
normally not require charging. If the generator will be idle
(not used) for long periods of time, apply power to the
battery charger receptacle via commercial power using a
power cord of adequate size.
NOTICE
If the generator will be idle (not used) for long periods of
time, ALWAYS keep power supplied to the generator's
internal battery charger to ensure adequate starting
capability.
BATTERY
CHARGER
AC IN
DC OUT
ENGINE BLOCK
HEATER
BATTERY CHARGER
120 VAC INPUT RECEPTACLE
OUTPUT TERMINAL
PANEL ASSEMBLY
ENGINE BLOCK HEATER
120 VAC INPUT RECEPTACLE
MAINTENANCE
TO CHASSIS
GROUND
GREEN 16AWG.
TO STARTER"B"
TERMINAL
RED 16AWG.