4. Press the TEST button (Figure 77) on the GFCI
receptacle and verify that the status LED turns OFF.
Figure 77. GFCI Receptacle (OFF)
5. Press the RESET button (Figure 78) to restore power
to the GFCI receptacle and verify that the status LED
is ON (GREEN).
Figure 78. GFCI Receptacle (ON/Restore)
6. If the status LED (Figure 79) is flashing (RED),
DO NOT use the GFCI receptacle. Replace it
immediately.
Figure 79. GFCI Receptacle (Red Flashing LED)
7. Repeat the above procedure for all other GFCI
receptacles.
PAGE 46 — DCA25SSIU4FC8 60 HZ GENERATOR • OPERATION MANUAL — REV. #0 (08/23/22)
TEST
BUTTON
STATUS
LED (OFF)
RESET
BUTTON
GREEN
STATUS
LED (ON)
RED
STATUS LED
(
FLASHING
)
GENERATOR STORAGE
For long-term storage of the generator the following is
recommended:
„ Drain the fuel tank completely. Treat with a fuel stabilizer
if necessary.
„ Completely drain the oil from the crankcase and refill if
necessary with fresh oil.
„ Clean the entire generator, internal and external.
„ Disconnect the battery.
„ Make sure engine coolant is at the proper level.
„ Cover the generator and store it in a clean, dry place.
„ If the generator is mounted on a trailer, jack the trailer
up and place it on blocks so the tires do not touch the
ground, or block and completely remove the tires.