Sidewall clearances

Side wall clearances are shown in the table below. Combustible
surrounds may be installed within clearances to the edge of the
opening as shown.
Combustible surround is permissible flush to opening when the
chase is vented AND fireplace venting ports are opened.
TOP OF UNIT
Figure 17.b Sidewall clearances
NOTICE
The listed clearances in sidewall drawing does not apply to recession,
unit cannot be recessed into a wall.

Finishing Safety Zone

Take special care when finishing underneath the fireplace door due to
the location of the gas valve and control board. Any screw can possibly
puncture one of these components resulting in either a non operational
unit or worse, a gas leak.
1" screw
safe zone
XG0230 - 052020
Sidewall clearances
DRSQ34
4"
DRSQ38
7"
Edge of opening
Sidewall
See
table
1" screw
safe zone
WARNING
The use of the fans when the Cool Wall Release OR Cool Wall
Advantage system is used will result in significantly higher wall
temperatures. These higher temperatures can negatively impact
the finished wall surface, art, and or mounted TV. Therefore,
Montigo STRONGLY RECOMMENDS that fans be disconnected
when the Cool Wall Release OR Cool Wall Advantage system is used.
This can be done through the remote control (See instructions)
or by disconnecting the fan harness. Montigo is NOT responsible
for damage to facing materials, and items placed above the
fireplace (eg. TV, artwork)

FULL LOAD VERSIONS:

Disable fans via remote
1. Turn the fireplace on, turn fans to off setting.
2. Partially take out one battery.
3. Hold both the Mode AND On/Off button.
4. Insert battery (while still holding the two
buttons), then release Mode button (keep
On/Off pressed).
5. Cycle through modes with Mode button until
you get to fan setting, with Down button set
fan function from Set to Clr.
6. Release On/Off button, turn the fireplace on.
There will be now be no fan mode on remote.
BASIC VERSIONS (IF OPTIONAL
FAN KIT ALREADY INSTALLED):
Disable fans via harness
1. Unplug the fan
harness that
connects power to
the speed control.