Montigo H Series Installation & Maintenance Manual

Montigo H Series Installation & Maintenance Manual

Pier, bay & corner
Table of Contents

Advertisement

Quick Links

WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury,
death, or property damage.
— Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neighbour's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a qualified
installer, service agency or the gas fitter.
DaNger
A barrier designed to reduce the risk of burns from the
hot viewing glass is provided with this appliance and
must be installed for the protection of children and
other at-risk individuals.
Installation & Maintenance Manual
®
C
US
HOT GLASS wIll
cAuse buRns.
DO NOT TOUCH glAss
untIl cooled.
NEVER Allow chIldRen
to touch glAss.
DIVINE
Pier, Bay & Corner
INDOOR DIRECT VENT GAS FIREPLACE
H38pfni-2 NG Traditional
H38pfli-2 Propane Traditional
Hl38pfni-2 NG Linear
Hl38pfli-2 Propane Linear
H38prni-2 NG Traditional
H38prli-2 Propane Traditional
Hl38prni-2 NG Linear
Hl38prli-2 Propane
• The installation of this fireplace must be done by a
qualified and certified gas appliance installer.
• Check local codes and read all instructions prior to
installation.
Notice
Installer: leave this manual with the appliance.
Consumer: Retain this manual for suture reference.
cautioN
Installation and service must be performed by a qualified installer,
service agency or the gas fitter.
DaNger
Read and understand this manual. Improper installation, adjustment,
alteration, service or maintenance can cause serious injury, property
damage or even death. For assistance or additional information
consult a qualified installer, service agency or the gas supplier.
WarNiNg
some materials used in the manufacturing process of this product can
expose you to benzene which is known in the state of california to
cause cancer and birth defects or other reproductive harm. For more
information go to www.P65warnings.ca.gov
H38Clni-2 NG Left Traditional
H38Clli-2 Propane Left Traditional
Hl38Clni-2 NG Left Linear
Hl38Clli-2 Propane Left Linear
H38Crni-2 NG Right Traditional
H38Crli-2 Propane Right Traditional
Hl38Crni-2 NG Right Linear
Hl38Crli-2 Propane Right Linear
xg0227 - 112718

Advertisement

Table of Contents
loading

Summary of Contents for Montigo H Series

  • Page 1 Installation & Maintenance Manual DIVINE Pier, Bay & Corner INDOOR DIRECT VENT GAS FIREPLACE H38pfni-2 NG Traditional H38Clni-2 NG Left Traditional H38pfli-2 Propane Traditional H38Clli-2 Propane Left Traditional Hl38pfni-2 NG Linear Hl38Clni-2 NG Left Linear Hl38pfli-2 Propane Linear Hl38Clli-2 Propane Left Linear H38prni-2 NG Traditional H38Crni-2 NG Right Traditional H38prli-2 Propane Traditional...
  • Page 2: Safety Alert Key

    Introduction Congratulations on your purchase of a Montigo Fireplace. with over 30 years of experience, Montigo is committed to providing you with a gas fireplace that is not only a beautiful addition to your space, but that is also designed and manufactured to the highest safety, reliability and engineering standards.
  • Page 3: Table Of Contents

    General Contents Safety Alert Key .................. 2 Section 5-2: Gas Pressure .................... 25 Section 5-3: GAS CONNECTION .................. 25 Introduction ..................2 Section 6: Finishing ................26 Section A: Before You Begin ..................4 Mantels & Surrounds ....................26 Installation Checklist ......................4 Fireplace Facing ......................
  • Page 4: Section A: Before You Begin

    • should it be impossible to meet the venting requirements laid out in Notice section 3: Venting, please contact a local Montigo dealer regarding the use of a Montigo Power Vent. • lay out the Vent run; calculating the required elbows and straight do not use this appliance if any part has been under water.
  • Page 5: Standard Installation Checklist

    General Standard Installation Checklist this standard installation checklist is to be used by the installer in conjunction with, not instead of, the instructions contained within this installation manual. customer date Installed: Install Address: location of Fireplace: Installer: dealer Phone: Model (circle one): h38PFnI-2, h38PFlI-2, hl38PFnI-2, hl38PFlI-2 , h38PRnI-2, h38PRlI-2, hl38PRnI-2, hl38PRlI-2 serial #:...
  • Page 6 General Rating Plate Sample figure 1.1 Rating Plate for IPI electronic ignition figure 1.2 Rating Plate for IPI electronic ignition xG0227 - 112718...
  • Page 7: Section 1: Product Dimensions

    General Section 1: Product Dimensions H38PR*I-2 Dimentions Please review the Installation checklist for general information on preparing for a successful 8" 5" 16 " installation of your fireplace. The fireplace may be installed in any location that maintains proper clearances to air conditioning ducts, electrical 16 "...
  • Page 8: H38Cl/Cr*I-2 Dimentions

    General H38CL/CR*I-2 Dimentions 8 " 7" 5" 8" 4 " 16 " 8 " 4" 6" 1007 4 " 8 " 16 " SUPPLY 1072 16 " 16 " 4 " 16 " H38DF-CR / HL38DF-CR DIMENSIONS TOLERANCES ARE IN: METRIC - MM 1.6 MM IMPERIAL - FRACTIONAL 1/16"...
  • Page 9: Section 2: Framing

    Installation Section 2: Framing Framing dimensions PRC Shelf over the fireplace, Rear vent exTerior note: when constructing the framed opening, please ensure there is wall access to install the gas line when the unit is installed CombusTible shelf 1" MIN. CombusTible header 12" MAX. Bay PRC: Frame in the enclosure Pier PFC: Frame in the enclosure 11"...
  • Page 10: Corner Framing Dimensions

    Installation Corner Framing dimensions Shelf over the fireplace, Rear vent note: when constructing the framed opening, please ensure there is 1" MIN. access to install the gas line when the unit is installed CombusTible shelf CombusTible header Corner CL/CR: Frame in the enclosure for the unit with framing 13"...
  • Page 11: Clearances

    Installation Clearances Removing the nailing Flange Extension When installing a shelf over the top of the fireplaces, the following The 4" nailing flange extension is shipped attached to the top edge of guidelines must be adhered to: the fireplace, see Figure 1. For Rear Vent applications, the minimum clearance is 1" from the rear of The nailing flange extension may be substituted with a piece of the fireplace to a wall, or any combustible materials, and 11"...
  • Page 12: Section 3: Venting

    Installation Section 3: Venting Montigo supplies a variety of direct venting and termination options. the direct vent termination location Must be selected such that it is the highest point in the venting assembly. It should also be selected such Flue Cover Plate 8"...
  • Page 13: Section 3-2: Installing A Roof Mounted Direct Vent Termination

    Installation Section 3-2: Installing a Roof Mounted Direct Vent Termination this section applies to installations where the direct vent termination PVtK1 termination will be roof mounted. storm collar 2' min Roof flashing Section 3-2-1: Venting Layout support ring selection of components and details of venting lay out should adhere support plate 32' max to the following guidelines:...
  • Page 14 Installation PVtK1 termination 2' min. storm collar Roof flashing PeXt solid sections Firestop support plate 32' max support ring Firestop 90° Elbow 12" max. figure 6.d Side vent, Roof mounted venting (1 = 90° bend). xg0227 - 112718...
  • Page 15: Section 3-3: Installing A Wall Mounted Termination 5''/8

    NOTE: If subject to a highly corrosive environment A termination with a MosR Frame is installed from the inside of the i.e. seaside, Montigo recommends using stainless steel termination. structure. these are commonly used in high-rise construction.
  • Page 16: Section 3-3-1: Venting Layout: Wall Mounted Termination

    Installation Section 3-3-1: Venting Layout: Wall Mounted Termination PRC & PFC Top Venting Graph heat shield 42'' Measure the vertical height from the fireplace hearth to the centre of Max. the termination and the horizontal run from the fireplace flue collar to termination the wall flange of the termination.
  • Page 17: Pfc Rear Venting Graph

    Installation PFC Rear Venting Graph 12'' Max. horozontal PXt extention Measure the vertical height from the fireplace hearth to the centre of run with no vertical lift the termination and the horizontal run from the fireplace flue collar to heat sheild the wall flange of the termination.
  • Page 18: Prc Rear Venting Graph

    Installation PRC Rear Venting Graph 12'' Max. horozontal PXt extention Measure the vertical height from the fireplace hearth to the centre of run with no vertical lift the termination and the horizontal run from the fireplace flue collar to heat sheild the wall flange of the termination.
  • Page 19: Corner Top Venting Graph

    Installation Corner Top Venting Graph heat shield 18'' Measure the vertical height from the fireplace hearth to the centre of Max. the termination and the horizontal run from the fireplace flue collar to termination the wall flange of the termination. Plot on the Venting Graph with an 'X'. If the 'X' falls on or above the top boundary of the shaded area, the installation is acceptable.
  • Page 20: Corner Rear Venting Graph

    Installation Corner Rear Venting Graph 64'' Measure the vertical height from the fireplace hearth to the centre of Max. the termination and the horizontal run from the fireplace flue collar to the wall flange of the termination. Plot on the Venting Graph with an 'X'. Flex or Rigid If the 'X' falls on or above the top boundary of the shaded area, the 26''...
  • Page 21: Section 3-3-2.2: Alternate Venting Components 5"/8

    Installation Section 3-3-2.2: Alternate Venting Components 5"/8" the following components are approved for use with Montigo products. Please contact your local Montigo dealer for further information. Component simpson duravent MetalFab selkirk Flexmaster Montigo Part number Part number Part number Part number Part number Part number...
  • Page 22: Section 3-3-3: Heat Shields 5''/8

    Installation Section 3-3-3: Heat Shields 5''/8'' Installing a Wall Mounted RHS8 heat shield Installing a Wall Mounted RHS101 Heat shield the Rhs8 heat shield cAnnot be used wIthIn 36" horizontal or 60" the Rhs101 heat shield Must be used where the Rhs8 termination vertically of the fireplace, (see figure 18a). For applications within these (Figure 18 and 18a) cAnnot be used.
  • Page 23: Section 4: Wiring

    Installation Section 4: Wiring bAtteRY PAcK 1.5V AA tYPe 1.5V AA tYPe sPARK gReen 1.5V AA tYPe MAIn Power whIte 120vac 60 hz 1.5V AA tYPe blAcK 6 amps blAcK sensoR MAIN ON/OFF swItch blue 885 PRoFlAMe OPTIONAL CPI/IPI SWITCH whIte yELLOW/GREEN PIlot...
  • Page 24: Pod - Pilot On Demand

    Installation POD - Pilot on Demand What is POD and CPI mode? Installing the CPI Jumper Cable This fireplace is equipped with an “On Demand” intermittent pilot 1). Access the control box. ignition system (IPI) which also includes a continuous pilot ignition (cPI) mode with an integrated seven day timer. In IPI mode, the pilot will light before the main burner, when the appliance is turned on using a wall switch, remote or from a thermostat.
  • Page 25: Section 5: Installing The Gas Line

    N.P.T. plug to be fitted with a hose barb (HSI only). 8 " 8 " 4 " • Montigo requires a service shut off valve be located in an accessible 2 " 8 " location to isolate the gas supply.
  • Page 26: Section 6: Finishing

    Installation Section 6: Finishing Mantels & Surrounds Finishing around the fireplace combustible mantels and mouldings may be safely installed over the note: national canadian gas Association mantel test requirements top and on the front of the fireplace provided that they do not project are for fire hazard prevention to combustible materials.
  • Page 27: Section 7: Screen Installation And Removal

    Installation Section 7: Screen Installation and Removal Removing the Screen Replacement Screens Grasp each top outer corner of the screen with your thumb and finger For replacement part order numbers, please refer to section and pull towards yourself. when the upper screen studs are free, lift "Replacement Parts" the screen at an angle from the lower slots from which the screen bottom tabs are held.
  • Page 28: Section 8: Installing & Removing The Door

    Installation Section 8: Installing & Removing the Door Removing the door STEP 4: the doors are removed in a few simple steps. Follow these below to Ensure the tool is firmly remove the horizontal access panel, unlatch the door buckles and, in the lower end of the remove the door. Replace in reverse order. slot, (as shown), then pull toward you.
  • Page 29: Section 9: Installing The Accessories

    WARNING: this appliance is intended for use only with the included LOG C Montigo burners and accessories. never install or add any additional or alternative media, rock wool or other material in this appliance. the use of additional or alternative materials may pose potential safety figure 22.e...
  • Page 30: Section 10: Start Up Sequence

    Operation Section 10: Start up Sequence For Your Safety - READ BEFORE LIGHTING: with American Flame Electronic Ignition WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. WARNING/ CAUTION: Hot while in operation.
  • Page 31: Sit Proflame 2 Electronic Ignition

    Operation SIT Proflame 2 Electronic Ignition For Your Safety - READ BEFORE LIGHTING: with American Flame Electronic Ignition stoP! Read the safety information above on this label. Turn fireplace "ON" using wall switch or remote control. Remove the lower horizontal access panel. If the Fireplace does not light, the System will cycle through two trials, (one minute audible clicking, thirty seconds of silence, and then another one Turn "ON"...
  • Page 32: Remote Operation

    Operation Remote Operation The Proflame 2 System consists of the following elements: 1. Pilot Assembly blue back lit lcd display 2. Proflame gas Valve. 3. Proflame 2 control Module On/Off key 4. wiring harness thermostat key 5. Variable speed fans (If applicable) Up/Down arrow key 7.
  • Page 33: Initializing The System For The First Time

    Operation Initializing the System for the first time Temperature Indication Display 1. set master override switch to off position. with the system in the "off" position, press the thermostat Key and the Mode Key at the same time. look at the lcd screen on 2.
  • Page 34: Remote-Flame Control

    Operation Remote-Flame Control Room Thermostat (Remote Control Operation) when you turn on the fireplace it starts on high. the proflame 2 has six (6) flame levels. each time you press the down Arrow Key the Remote control can operate as a room thermostat. the once the flame height will reduce by one step.
  • Page 35: Disabling Thermostat

    Operation Disabling Thermostat Fan Speed Control the fireplace is equipped with optional hot air circulating fans. some jurisdictions and bedroom installations require the the speed of the fans can be controlled by the Proflame system. thermostat to be disabled. the fan speed can be adjusted through six (6) speeds. to activate this function use the Mode Key, see Figure 27, to index to the fan 1.
  • Page 36: Section 10: Cleaning And Maintenance

    Operation Section 10: Cleaning and Maintenance General Hi-Lo Burner Adjustment: (SIT 820). • Have the fireplace and installation inspected yearly. The inspection To adjust the flames, locate the black knob marked 'Hi-Lo', in the centre must include, but is not limited to, the following: of the gas control valve •...
  • Page 37: Troubleshooting Sit 820

    1. check wiring will not light 2. check wall switch for proper connection If your fireplace still does not operate correctly, consult your local Montigo dealer. All service and repairs should be performed by a qualified Technician. spare parts and accesories are available from your local Montigo dealer. xg0227 - 112718...
  • Page 38: Replacement Parts

    Valve Rgc1006 Propane gas Valve Rgc1005 ng Pilot RPA020 Propane Pilot RPA021 Rdth38cl01 RDTH38CL01 ng burner Rsch38cl2 RSCH38CL2 contact local Montigo dealer Propane burner DIMENSIONS ARE IN INCHES NAME DATE Description H38D TOLERANCES: 01/26/2015 Drawn by FRACTIONAL 1/32" thermocouple...
  • Page 39: Indoor Fireplace In Protected Outdoor Applications

    Appendix Indoor fireplace in protected outdoor applications This fireplace may be installed into outdoor locations provided they are suitably protected from direct water impingement. However, all installation clearances in the appliance manual must be observed. Framing, clearances to combustibles, Mantel heights, Facing Requirements, Venting Installation, etc.
  • Page 40: Appendix A: Venting Terminations

    Appendix Appendix A: Venting Terminations Covered Covered Alcove Detail Alcove Detail Vinyl Siding 2’ 2’ 2’ 2’ 17.5’’ 29.5’’ 11.5’’ 17’’ Must use Vinyl Siding Termination Shield location Canada* usa** clearance to the termination frame above grade, veranda, porch, deck, or balcony 12 inches 12 inches clearance to top of doors or operable windows...
  • Page 41: Appendix B: Warranty

    (collectively referred to herein as "the companies"), warrants the If the components of the appliance covered by this warranty Montigo gas appliance (referred to herein as 'the appliance') to are found to be defective within the time frame stated (see the...
  • Page 42 Montigo dealer (www.Montigo.com) or contact Montigo direct at techsupport@ montigo.com. ensure you have your sales receipt and the model and serial number of your appliance. DO NOT ATTEMPT TO DO ANY SERVICE WORK YOURSELF If you cannot locate the installing dealer, or nearest dealer/ distributor, you must notify the companies in writing.
  • Page 43: Appendix C: Amendment

    Appendix Appendix C: Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise nFPA-54 section 10.5.4.2 by adding a second exception as 4. InsPectIon. the state or local gas inspector of the side wall follows: horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes...
  • Page 44 Installation & Maintenance Manual PIER, BAY & CORNER Indoor direct vent gas Fireplace xg0227 - 112718...

Table of Contents