Drsq38 Co-Linear Venting Into Existing Masonry Chimney - Montigo DelRay Square DRSQ34NI Installation & Maintenance Manual

Indoor direct vent gas fireplace
Table of Contents

Advertisement

DRSQ38 Co-linear venting into existing masonry chimney
The appliance can be adapted to co-linear applications using an existing
chimney. The appliance must not be connected to a chimney flue serving
a separate solidfuel burning appliance such as a wood burning fireplace.
• Maximum 30 feet vertical pipe
• Minimum 10 feet vertical
• Restrictor usage recommended for longer vertical runs
• Keep the flexible liner as straight as possible, avoid unnecessary
bending
• A maximum of two certified couplers may be used per length of 3" liner
• DelRay Square co-linear installation requires reducing from 5/8 to
Duravent 4x6⅝ (Alternatively, 46DVA-AD-M1 adaptor could be used
with DRSQCOL47 collar conversion)
(High wind termination)
Co-linear
portion of
vent system
may only be
installed within
the fireplace
cavity and
chimney.
46DVA-CLAA
(Converts Duravent Direct vent to Co-Linear)
58DVA-X46
(Part reduces Duravent 5/8 to Duravent 4/6⅝)
58DVA-AD-M1
(Part converts Montigo 5/8 to Duravent 5/8)
Hearth
Figure 99.a Co-linear top vented configuration.
Approved termination / Flex Kits
Component
Duravent P/N
Termination and flex
46DVA-CL33
kits
NOTES
• High Wind Termination Cap
with 18" x 18" base plate
• Two 35 foot Aluminum
Flexible Liner Lengths
• Exhaust identified with red
tape at both ends
• Clamps
• Hardware Pack
XG0230 - 052020
46DVA-CL33K
10'
Min.
Dual 3"
liners
Selkirk P/N
4DT-33IK35VB
• High Wind Termination Cap
with 18" x 18" base plate
• Two 35 foot Aluminum
Flexible Liner Lengths
• Exhaust identified with red
tape at both ends
• Clamps
• Hardware Pack
The unit must be fully enclosed while maintaining clearances to
combustibles detailed elsewhere in this manual
30'
Max.
(Converts Duravent Direct vent to Co-Linear)
(Part converts Montigo 5/8 to Duravent 5/8)
Hearth
Installation
NOTICE
46DVA-CL33K
(High wind termination)
Co-linear
portion of
vent system
may only be
installed within
the fireplace
Dual 3"
cavity and
liners
chimney.
46DVA-CLAA
58DVA-AD-M1
58DVA-X46
(Part reduces Duravent 5/8 to Duravent 4/6⅝)
Figure 99.b Co-linear rear vented configuration.
DRSQ38
58DVA-AD-M1
(Part converts Montigo 5/8 to Duravent 5/8)
58DVA-X46
(Part reduces Duravent 5/8 to Duravent 4/6⅝)
46DVA-CLAA
(Converts Duravent Direct vent to Co-Linear)
46DVA-CL33
OR
4DT-33IK35VB
10'
Min.
30'
Max.
21

Advertisement

Table of Contents
loading

Table of Contents