10. Technical Data - Rangemaster CLA110DFF User's Manual & Installation Instructions

Table of Contents

Advertisement

10. Technical Data

THE COOKER IS CATEGORY: CatII 2H3+ . It is supplied set for group H natural gas. A conversion kit from NG to LP is available for
the cooker. INSTALLER: Please leave these instructions with the user. DATA BADGE LOCATION: Cooker back, serial number
repeater badge below oven door opening. COUNTRY OF DESTINATION: GB, IE.
Connections
See the appliance badge for test pressures.
Gas
Natural Gas
Butane
Propane
Dimensions
Model
Overall height
Overall width
Overall depth
Minimum height above the hotplate
Hotplate Ratings
Hotplate
Wok burner
Rapide/ Large Burner
Semi Rapide / Medium Burner
Auxiliary / Small Burner
* The valves in this cooker are fitted with adjustable bypass screws. The cooker is supplied with the bypass screws set for Natural Gas. For LPG conversion the
bypass screws must be screwed all the way down.
Hotplate energy saving tips
Use cookware with a flat base.
Use the correct size cookware.
Use cookware with a lid.
Minimise the amount of liquid or fat.
When liquid starts boiling, reduce the setting.
Consumption is based on G30.
(Rp ½ at rear right-hand side)
Bypass
Screw*
62
4.0 kW
40
3 kW
32
1.7 kW
28
1 kW
20 mbar
29 mbar
37 mbar
minimum 905 mm
600 mm excluding handles, 648 mm including handles
Natural Gas G20 20 mb
Injector
148
134
109
75
Oven energy saving tips
Cook meals together, if possible.
Keep the pre-heating time short.
DO NOT lengthen cooking time.
DO NOT open the oven door during the cooking period.
DO NOT forget to turn the appliance off at the end of
cooking.
33
Electric
230/400 V 50 Hz
Classic 110 Dual Fuel
maximum 930 mm
1096 mm
650 mm
L.P. Gas 29 / 37 mb
4.0 kW (291 g/h)
3.0 kW (218 g/h)
1.7 kW (124 g/h)
1.0 kW (73 g/h)
Injector
103
87
68
51

Advertisement

Table of Contents
loading

This manual is also suitable for:

Classic 110 dual fuel

Table of Contents