Middle Left CHT/EGT Graph
The GI 275 EIS provides a 4 or 6-cylinder CHT/EGT graph in the middle left of the Main EIS page. This
section displays CHT, EGT, and if configured, Primary EGT or TIT (single or dual) in a bar graph layout
with digital readouts above the graph for the hottest cylinder or the user-selected cylinder. Refer to Figure
E-4 for examples.
Middle Right Strip Gauges
The GI 275 EIS provides a section in the middle right of the display that arranges up to four strip gauges or
up to three strip gauges with two digital gauges. This section layout will differ depending on the displayed
gauges and the alerting lines configured with the corresponding gauge. Refer to Figure E-5 for layout
examples.
The gauges in the middle right of the Main EIS page follow a gauge priority scheme as shown below.
Number 1 is the highest priority gauge and number 17 is the lowest priority gauge. The section populates
the gauge layout from top to bottom following the prioritization scheme listed below.
The following are exceptions to the priority list:
If AUX/Tip tanks are configured and at least one digital gauge is configured with a red/yellow
alert, this gauge will take the top slot
The Fuel Flow gauge will always be placed in the fourth slot (near the fuel quantity) unless it is
unmarked with an alert and four other gauges are marked with a red/yellow alert
(With Red or Yellow Markings)
1. Oil Pressure
2. Oil Temperature
3. Fuel Flow
4. Fuel Pressure
5. Carb Temp
6. CDT
7. IAT
190-02246-14