10.3 Maintenance work

For maintenance work to be carried out, the following prerequisites must be fulfilled and the respective 
preparatory tasks must have been completed.

10.3.1 Turbidity check of the purified condensate

Tools
No tool necessary
Illustration
Prerequisites
Material
No material necessary
1. Remove the reference turbidity tube from the
holder and fill it with a water sample from the 
service valve [D].
2. Compare the sample with the reference turbidity
on the lower half of the reference turbidity tube.
The sample is clearer than the reference turbidity:
0 The QWIK‑PURE
The sample is equally or more turbid than the
reference turbidity
0 Replace the filter cartridges immediately.
3. Document the result of the turbidity test.
QWIK-PURE
Protective equipment
Always to be worn:
Description
works perfectly.
®
®