Description / explanation
11. Tighten the 4 hexagon socket screws with
a tightening torque of 1 Nm ±0.1 Nm
(0.74 ft-lb ±0.74 ft-lb).
12. Install the compressed air connection.
13. Tighten the hose clamp hand-tight.
14. Restore the compressed air supply.
15. After completing the service on the solenoid
valves, press and hold down the Enter button for
3 seconds.
0 The status LED STATUS BAR lights up green.
0 The display will switch to the START MENU
3 sec
screen.