QWIK-PURE
®
Error or fault pattern
WARNING 3
Illogical sensor values
(e.g. High Level (HL) sensor and
High Level Alarm (HLA) sensor
covered but Low Level (LL)
sensor uncovered)
WARNING 4
Permanently high oil quantity
detected in measuring chamber
116 | 124
Possible cause
1. Soiled FRC sensors
2. Very large quantity of oil in the
measuring chamber due to a
large oil inflow (e.g., oil leaking)
1. Filter cartridges can no longer
absorb oil
2. Permanently high quantity of
oil in the measuring chamber
due to a large oil inflow (e.g., oil
leaking)
Installation and operation manual
Measure
Clean the FRC sensors (see section
"10.3.5 Cleaning" on page 98)
Monitor whether the error
message disappears after a
few discharge cycles. Contact
BEKO TECHNOLOGIES Service
(see "1.1 Contact" on page 5)
Replacing filter cartridges (see
section "10.3.2 Replacing filter
cartridges" on page 84)
Check oil content in condensate
inlet