Illustration
3 sec
Description / explanation
The current status of the piston is displayed.
0 The status LED PISTON flashes red.
0 The status LED STATUS BAR lights up red.
3. Press and hold the Service button for 3 seconds.
The discharge process is started.
0 The piston in the FRC will close the
condensate inlet from the pressure relief
chamber into the FRC.
0 The measuring chamber is supplied with
auxiliary air at timed intervals.
0 The condensate is passed into the filter 
cartridges.
0 The status LED STATUS BAR flashes blue 
and indicates the remaining time until the
service.
Status LED STATUS BAR
4/4 of the length flashes blue
3/4 of the length flashes blue
2/4 of the length flashes blue
1/4 of the length flashes blue
When the minimum filling level in the measuring 
chamber is reached, the discharge process stops.
0 The piston in the FRC will open the
condensate inlet from the pressure relief
chamber into the FRC.
0 The status LED STATUS BAR is permanently
lit blue.
0 The measuring chamber is no longer
pressurised with auxiliary air.
QWIK-PURE
®
Remaining time
100 %
75 %
50 %
25 %