Panasonic PT-SRZ34KC Operating Instructions Manual page 162

Table of Contents

Advertisement

Note
f Even if [MECHANICAL SHUTTER] is set to [DISABLE], the projector will go into the standby status with the mechanical shutter closed when
[SHUT-OFF] is set to [CLOSE] and the power is turned off.
Setting the shutter synchronization function
The shutter synchronization function is a function to synchronize the shutter operation of the specified projector
to other projectors, and the effect using the shutter function including the fade in/fade out operation can be
synchronized.
To use the shutter synchronization function, it is necessary to connect the projectors targeted for synchronization
in a loop with daisy chain connection using the <多台投影机同步输入> terminal and the
<多台投影机同步输出> terminal. For details of how to connect the projectors, refer to "Connecting example when
using the contrast synchronization function/shutter synchronization function" (x page 61).
1)
Press as to select [SHUTTER SETTING].
2)
Press the <执行> button.
f The [SHUTTER SETTING] screen is displayed.
3)
Press as to select [MULTI PROJECTOR SYNC].
4)
Press the <执行> button.
f The [MULTI PROJECTOR SYNC] screen is displayed.
5)
Press as to select [MODE].
6)
Press qw to switch the item.
f The items will switch each time you press the button.
[OFF]
[MAIN]
[SUB]
f When anything other than [OFF] is selected, the diagnostic result is displayed in [LINK STATUS], indicating
if all the projectors including the projectors targeted for synchronization are correctly connected, and if
[MODE] is correctly set.
[LINKED]
[NO LINK]
7)
Press as to select [SHUTTER SYNC].
8)
Press qw to switch the item.
f The items will switch each time you press the button.
[OFF]
[ON]
Note
f The [MULTI PROJECTOR SYNC] setting item is common with the following menu item.
g The [PROJECTOR SETUP] menu → [MULTI PROJECTOR SYNC]
For details on contrast synchronization function, refer to the [PROJECTOR SETUP] menu → [MULTI PROJECTOR SYNC] (x page 192).
f The shutter synchronization function will operate when all of the following conditions are fulfilled.
g All the projectors to be linked are connected in a loop with the daisy chain connection. (Maximum 64 projectors)
g [MODE] on only one projector that is linked is set to [MAIN], and [MODE] on all other projectors are set to [SUB].
g [SHUTTER SYNC] on the projectors to perform the shutter synchronization is set to [ON].
f It is possible to set [SHUTTER SYNC] to [OFF] for the projectors that are linked but not to synchronize.
f The shutter operation by the shutter synchronization function will follow the setting of the [DISPLAY OPTION] menu → [SHUTTER
SETTING] on the projector that [MODE] is set to [MAIN].
162 - ENGLISH
Chapter 4 Settings — [DISPLAY OPTION] menu
Select this item when the contrast synchronization function and the shutter synchronization function
are not used.
Select this item when the contrast synchronization function or the shutter synchronization function is
used.
Set this item only on one of the linked projectors that becomes the synchronization source of the
shutter operation.
Select this item when the contrast synchronization function or the shutter synchronization function is
used.
Set this item in all the linked projectors excluding the projector set as the [MAIN].
All the projectors are correctly connected, and correctly set. They are in the condition that the contrast
synchronization function or the shutter synchronization function can be used.
The projectors are not correctly connected, or not correctly set. Check the cable connection status
and the projector setting for each projector that is linked.
Select this item when the shutter synchronization function is not used.
Select this item when the shutter synchronization function is used.

Advertisement