SFLT NO
CAC_CIS 3
CAC_MFC 0
CLS
UNR FBD WTA LPR MTD FND HTA ADD HFD
MWD LMPN RMMD SMWD AAD IMD XHD IRD NID OLD VCE DRG1
POD DSX VMD CMSD SLKD CCSD SWD LND CNDD
CFTD SFD MRD DDV CNID CDCA MSID DAPA BFED RCBD
ICDD CDMD LLCN MCTD CLBD AUTU
GPUD DPUD DNDD CFXD ARHD CLTD ASCD
CPFA CPTA HSPD ABDD DELD CFHD FICD NAID DNAA BUZZ AGRD MOAD
UDI RCC HBTD AHD IPND DDGA NAMA MIND PRSD NRWD NRCD NROD
DRDD EXR0
USMD USRD ULAD CCBD RTDD RBDD RBHD PGND FLXD FTTC DNDY DNO3 MCBN
CPND_LANG ENG
HUNT 1561
PLEV 02
AST
IAPG 0
AACS NO
ITNA NO
DGRP
MLWU_LANG 0
DNDR 0
KEY
00 SCR 1560 0
ANIE 0
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
DATE
7 OCT 2003

Figure 5 Sample LD11 TUI Port Switch Configuration

Observation Port Configuration
Overlays 11, 23 and 32 are used to configure observation ports on the Nortel
Remote Agent Observe card.
The sequence of configuration is:
1. Configure ACD queue for use with Nortel Remote Agent Observe in LD23
as described below. Each observation port is required to be part of an ACD
queue in order to be able to observe.
2. Configure the observation ports as M2616 in LD11 as described below.
3. Enable the card in LD32
Overlay 23 – If there is no ACD queue already configured, one will need to be
configured for Nortel Remote Agent Observe.