5-18.
CPU
Note
The radiation sheet 0.5 (30X30) is not reusable. Prepare new parts in advance.
Preparation
1.
Remove the top panel assembly. (Refer to
2.
Remove the iAP-005 board assembly. (Refer to
Removal
1.
Remove the four screws, the four step washers and the four compression springs and detach the heat sink.
2.
Remove the radiation sheet 0.5 (30X30).
Step washers
Compression springs
Heat sink
Radiation sheet
0.5 (30X30)
PWS-110RX1A
"5-4. Top Panel
"5-17. iAP-005 Board
B2.6 x 5
Assembly".)
Assembly".)
5-28