4-1.

Periodic Maintenance

Inspect and replace parts regularly to maximize and maintain the performance of the unit.
4-1-1.

Digital Hours Meter

The elapsed operation time of the unit is displayed. Use this digital hours meter as a guide to periodic check/replacement.
Displaying Digital Hours Meter
Operation Hours data is shown on the Diagnosis page of the Maintenance Web screen.
For details of the Maintenance Web screen, refer to Operation Manual for PWS-100 Maintenance Web Application.
Item
Operation Hours
4-1-2.

Periodic Replacement Parts

This section describes the recommended replacement parts and recommended replacement time.
This table does not describe the guarantee period of part.
The replacement period of each part is changed according to the environment and condition.
Lo-
Part name
cati-
on
FAN, DC
(HPR-48 board)
PWS-110RX1A
Section 4

Periodic Maintenance and Inspection

Description
Total power-on hours (unit: hour, resettable)
Sony parts No.
Hour meter
(Menu Item)
Total power-on hours
1-855-344-21
!
(OPERATION
HOURS)
Check/replacement
Reference
period
section
About 5 years
"Replace-
(When used for 12
ment of Fan"
hours a day.)
in the
MSQS321
service man-
ual
4-1