Snmp Trap Messages - Sony PWS-110RX1A Service Manual

Network rx station and optional power supply
Hide thumbs Also See for PWS-110RX1A:
Table of Contents

Advertisement

2-2.

SNMP Trap Messages

SNMP trap messages are output from the unit through the SNMP.
Message
Description
POWER SUPPLY x
An abnormality was detected in the power
ERROR
supply unit x.
FAN x ERROR
An abnormality of the fan assembly FANx
was detected.
HIGH TEMPERA-
The internal temperature has risen.
TURE
LOW BATTERY
The backup battery voltage has dropped.
DIO-98 INITIAL
Failed to initialize the DIO-98 board.
ERROR
SMBUS ERROR
An error occurred in the SMBUS interface of
the MB-1204 board.
EEPROM ERROR
An error occurred in the EEPROM I/F inter-
face of the MB-1204 board.
POWER SUPPLY x
The rotating speed of the fan in the power
WARNING
supply unit x has decreased.
FAN x WARNING
The rotating speed of FANx has decreased.
SSD LIFETIME
The SSD module (M.2 assembly) has reached
the end of its life.
Further use of the SSD module decreases the
reliability of stored data and causes eventual
failure of data writing.
• Power supply unit No.: A, B
• Fan assembly No.: 1 to 5
PWS-110RX1A
Action
Replace the power supply unit x.
Replace the faulty fan assembly.
Clean the air filter and readjust the ambient temperature
setting.
Replace the backup battery with a new one.
Turn off and on the unit. If the same error recurs, replace
the DIO-98 board.
Turn off and on the unit. If the same error recurs, replace
the MB-1204 board.
Turn off and on the unit. If the same error recurs, replace
the MB-1204 board.
It can be used continuously.
We recommend that you replace parts as soon as possible.
It can be used continuously.
We recommend that you replace parts as soon as possible.
It can be used continuously.
We recommend that you replace parts as soon as possible.