2 Overview
AEM components
553-3201-200 Standard 1.0 April 1993
Meridian SL-1 systems (upgraded) capable of operating on Generic
X11 Release 16, or later, software.
An individual AEM can be placed in a column with other Meridian 1
modules in system options 21, 51, 61 or 71. This document explains how to
install a stand-alone AEM and add an AEM to a Meridian 1 column.
The AEM is equipped with a Module Power Distribution Unit (MPDU) on
the left (looking at the front of the AEM).
The MPDU provides two circuit breakers (see Figure 1). The top breaker
controls power to the left Application Module (the one closer to the
MPDU). The bottom breaker controls power to the second Application
Module (on the right of the AEM).
Figure 1xxx
AEM with Application Modules-front view
Breaker for left-
side module
Breaker for
Module Power
right-side
Distribution Unit
module
Left-side Application